 New are out 3F3 and 3F2 Auto Generator Control unit when commanded sends the proper signal to the generator to prime, start and stop.  This Unit is smaller, Space saving and more affordable.

Efficient Generator Control with Stop/Prime, Start, and Stop Functionality

Efficiently control your generator with our Auto Start/Stop Unit, designed to seamlessly integrate with Victron equipment and compatible generators like Onan and NPS and others

What It Does: This unit converts a constant signal from Victron or other devices into a momentary signal to start or stop your generator. It's designed for generators like Onan and NPS/other that use remote start controllers and ensures proper operation by converting the signal to a simple momentary signal controlled by timers.

Features:

  • Prime, Start, and Stop functionality.

  • Manual control buttons (start, stop).

  • Built-in fuse protection for Victron relays/device protection 2amp.

  • Compatible with Onan, NPS, and other LP gas and Gasoline generators.  For Diesel's such as the QD setups in RV's or ones with remote start it should work but verify with us for capability.  Portables and direct connect to control switches may require another setup.

  • Prime feature to improve generator performance after long periods of inactivity.

  • Safely shuts down running generators to prevent accidental damage.

Requirements:

  • Installation by someone that understands electrical systems.

  • Compatible with Victron Cerbo GX, BMV-712 battery monitor, Multiplus II inverter/chargers programable relays.

  • Compatibility with other Onan, NPS, or similar generators that use 2 wires to control start and stop.

  • Stand-alone diesel and portable generators may require a different configuration. Contact us if you have one of these.

  • May work with other controlling manufacture’s devices contact us for suitability

Compatibility:

  • Operates on 12V systems.

  • Accepts signal outputs from 3V to 24V.

  • Signal ground must share the same source as the generator ground.

  • Default configuration uses a single signal for both start and stop.

  • Configurable for separate start and stop signals—contact us for assistance.

I you have any questions feel free to contact us.  We are trying to keep this DIY friendly while also having offerings for those who don't have all the tools, equipment and knowledge to do certain projects or time constrained.  For some buying all the tools needed for the project is more expensive than the project itself and we recognize this, so we are here to help if you want to go Diy or not.  

Need help? Feel free to message us with any questions! This product is in stock and available for backorder if needed.

 

Tags: Generator Auto Start/Stop Unit, Generator Stop/Prime  Start/Stop,Victron, RV Products, Generator Parts, Off-Grid Power, Solar System, Generator Accessories, Automatic Generator Control, Off-Grid Power Solutions,Onan,NPS, Cummins, Dometic, Generac, Kohler, Powertech 

unit-w-cable-2.png

2F2 Generator Start Stop units available.  Also will be available for DIY kits and parts.  Unit has Automotive connector for easy removal if needed

unit-w-cable.png

Unit will come with a 24" pig tail cable.  That puts the standard length at 32". longer tails may be available upon request and standard requested lengths are established.

20241217_115153[1].jpg

This NEW 3F3 unit has Start/Stop and  independent Prime. Ideal for dual fuel generators such as the FelexPower 4000i & 5000i or other generators that need this configuration. A Turn off prime function  when on LP gas is being used.

bottom of page